STRUCTURAL ANALYSIS

Vent & Port Sizing

Altimeter static ports for accurate readings and pressure relief vents to prevent premature separation.

Back to Structural Analysis
01

Vent Types

TypePurposeTypical Size
Altimeter portsPressure sampling for altitude3-6mm diameter
Pressure reliefPrevent over-pressure1.5-3mm diameter
Ejection bay ventsPost-deployment decay3-6mm diameter
02

Altimeter Ports

Ports must allow pressure equalization fast enough to avoid altitude measurement errors. The Stroick formula (widely used):

Volume < 100 in³
d=V400d = \frac{V}{400}
Volume ≥ 100 in³
d=2V6397.71d = 2\sqrt{\frac{V}{6397.71}}
ddPort diameter (inches)VVBay volume (cubic inches)

Minimum Ports

3

Evenly spaced

Recommended

4

Best gust immunity

Port Placement

Locate on cylindrical section parallel to airflow. Avoid proximity to nose cone shoulder, fins, and rail buttons.
03

Pressure Relief

Without pressure relief, altitude changes create internal over-pressure:

AltitudePressureΔP from Sea Level
0 m101.3 kPa0
1000 m89.9 kPa11.4 kPa
3000 m70.1 kPa31.2 kPa
5000 m54.0 kPa47.3 kPa

Premature Separation

A 4" rocket at 3000m can experience 254 N (57 lbf) force on the nose cone from pressure differential — easily overcoming friction fit!
04

Sizing Guidelines

DiameterBay LengthPort Diameter
38mm150mm1.5mm (1/16")
54mm180mm2.4mm (3/32")
75mm230mm3.2mm (1/8")
98mm300mm4.0mm (5/32")
150mm450mm5.5mm (7/32")

For pressure relief (friction-fit nose):

Relief Vent Area
Avent≈0.5−1.0%×AcrossA_{vent} \approx 0.5-1.0\% \times A_{cross}